Skip to main content

CVE-2024-4641

6.3
MEDIUMCVSS v3.1 Base Score
0.48%
LOW RiskEPSS (65th percentile)

OnCell G3470A-LTE Series firmware versions v1.7.7 and prior have been identified as vulnerable due to accepting a format string from an external source as an argument. An attacker could modify an externally controlled format string to cause a memory leak and denial of service.

Published: 6/25/2024
Modified: 3/10/2025
Back to CVE Lookup

Vulnerability Summary

CVSS v3 Score

6.3MEDIUM

CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:L/I:L/A:L

EPSS Score (Exploitation Probability)

0.48%LOW Exploitation Risk
65th percentile

This vulnerability has a 0.48% probability of being exploited in the next 30 days, ranking higher than 65% of all scored CVEs.

CWE Classification

Related Vulnerabilities

Same Weakness Type(CWE-134)

CVE-2024-23113CRITICAL 9.8

A use of externally-controlled format string in Fortinet FortiOS versions 7.4.0 through 7.4.2, 7.2.0 through 7.2.6, 7.0.0 through 7.0.13, FortiProxy versions 7.4.0 through 7.4.2, 7.2.0 through 7.2.8, 7.0.0 through 7.0.14, FortiPAM versions 1.2.0, 1.1.0 through 1.1.2, 1.0.0 through 1.0.3, FortiSwitchManager versions 7.2.0 through 7.2.3, 7.0.0 through 7.0.3 allows attacker to execute unauthorized code or commands via specially crafted packets.

2/15/2024
CVE-2023-5746CRITICAL 9.8

A vulnerability regarding use of externally-controlled format string is found in the cgi component. This allows remote attackers to execute arbitrary code via unspecified vectors. The following models with Synology Camera Firmware versions before 1.0.5-0185 may be affected: BC500 and TC500.

10/25/2023
CVE-2022-35875CRITICAL 9.8

Four format string injection vulnerabilities exist in the XCMD testWifiAP functionality of Abode Systems, Inc. iota All-In-One Security Kit 6.9X and 6.9Z. Specially-crafted configuration values can lead to memory corruption, information disclosure and denial of service. An attacker can modify a configuration value and then execute an XCMD to trigger these vulnerabilities.This vulnerability arises from format string injection via the `wpapsk` configuration parameter, as used within the `testWifiAP` XCMD handler

10/25/2022
CVE-2022-35244CRITICAL 9.8

A format string injection vulnerability exists in the XCMD getVarHA functionality of abode systems, inc. iota All-In-One Security Kit 6.9X and 6.9Z. A specially-crafted XCMD can lead to memory corruption, information disclosure, and denial of service. An attacker can send a malicious XML payload to trigger this vulnerability.

10/25/2022
CVE-2022-27177CRITICAL 9.8

A Python format string issue leading to information disclosure and potentially remote code execution in ConsoleMe for all versions prior to 1.2.2

4/1/2022

Similar SeverityMEDIUM

CVE-2026-34926MEDIUM 6.7

A directory traversal vulnerability in the Apex One (on-premise) server could allow a pre-authenticated local attacker to modify a key table on the server to inject malicious code to deploy to agents on affected installations. This vulnerability is only exploitable on the on-premise version of Apex One and a potential attacker must have access to the Apex One Server and already obtained administrative credentials to the server via some other method to exploit this vulnerability.

5/21/2026
CVE-2026-45498MEDIUM 4

Microsoft Defender Denial of Service Vulnerability

5/20/2026
CVE-2026-40243MEDIUM 4.8

Incus is a system container and virtual machine manager. In versions before 7.0.0, broken TLS validation logic in the OVN database connection logic can allow connections to an attacker's OVN database. The OVN client implementations disable Go standard TLS server verification and replace it with custom peer-certificate verification logic. That replacement verifier does not anchor trust in the configured CA certificate. Instead, it constructs the verification root set from certificates supplied by the peer during the handshake, so the configured CA is parsed but not used as the trust anchor for the final verification decision. In OVN-enabled deployments that use these SSL database connection paths, an attacker able to impersonate or intercept the OVN endpoint on the management network can present a rogue self-signed certificate chain, and Incus will accept this certificate as valid. This issue defeats the intended CA-based trust model for OVN database connections and permits endpoint impersonation by an active attacker in a suitable network position. This issue is fixed in version 7.0.0.

5/6/2026
CVE-2026-40197MEDIUM 6.5

Incus is a system container and virtual machine manager. In versions before 7.0.0, missing validation logic in the storage volume import logic allows an authenticated user with access to the storage volume feature to cause the Incus daemon to crash. The custom volume backup import subsystem contains a nil-pointer dereference vulnerability during import operations. In the snapshot import loop, the daemon iterates over entries from `srcBackup.Config.VolumeSnapshots` and assumes that each slice element is initialized, then dereferences fields such as `Name`, `Config`, `Description`, `CreatedAt`, and `ExpiresAt` without first validating the element itself. Because the yaml unmarshaler accepts explicit null array elements from an attacker-controlled index.yaml and converts them into nil pointers inside the slice, an attacker can supply a backup archive containing a null entry in the volume_snapshots array. This causes a nil-pointer dereference during custom volume import and terminates the daemon, resulting in denial of service on the affected node. Repeated use of this issue can be used to keep Incus offline, causing a denial of service. This issue is fixed in version 7.0.0.

5/6/2026
CVE-2026-8033MEDIUM 5.3

A vulnerability has been found in PicoTronica e-Clinic Healthcare System ECHS 5.7. This affects an unknown function of the file /cdemos/echs/api/v2/ of the component Response Header Handler. Such manipulation leads to information disclosure. The attack may be performed from remote. The exploit has been disclosed to the public and may be used. Upgrading to version 5.7.1 mitigates this issue. It is suggested to upgrade the affected component. The vendor was contacted early, responded in a very professional manner and quickly released a fixed version of the affected product.

5/6/2026