Skip to main content

CVE-2023-38433

7.5
HIGHCVSS v3.1 Base Score
53.20%
MEDIUM RiskEPSS (98th percentile)

Fujitsu Real-time Video Transmission Gear "IP series" use hard-coded credentials, which may allow a remote unauthenticated attacker to initialize or reboot the products, and as a result, terminate the video transmission. Affected products and versions are as follows: IP-HE950E firmware versions V01L001 to V01L053, IP-HE950D firmware versions V01L001 to V01L053, IP-HE900E firmware versions V01L001 to V01L010, IP-HE900D firmware versions V01L001 to V01L004, IP-900E / IP-920E firmware versions V01L001 to V02L061, IP-900D / IP-900ⅡD / IP-920D firmware versions V01L001 to V02L061, IP-90 firmware versions V01L001 to V01L013, and IP-9610 firmware versions V01L001 to V02L007.

Published: 7/26/2023
Modified: 11/21/2024
Back to CVE Lookup

Vulnerability Summary

CVSS v3 Score

7.5HIGH

CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H

EPSS Score (Exploitation Probability)

53.20%MEDIUM Exploitation Risk
98th percentile

This vulnerability has a 53.20% probability of being exploited in the next 30 days, ranking higher than 98% of all scored CVEs.

CWE Classification

Related Vulnerabilities

Same Weakness Type(CWE-798)

CVE-2026-22769CRITICAL 10

Dell RecoverPoint for Virtual Machines, versions prior to 6.0.3.1 HF1, contain a hardcoded credential vulnerability. This is considered critical as an unauthenticated remote attacker with knowledge of the hardcoded credential could potentially exploit this vulnerability leading to unauthorized access to the underlying operating system and root-level persistence. Dell recommends that customers upgrade or apply one of the remediations as soon as possible.

2/17/2026
CVE-2026-1221CRITICAL 9.8

PrismX MX100 AP controller developed by BROWAN COMMUNICATIONS has a Use of Hard-coded Credentials vulnerability, allowing unauthenticated remote attackers to log in to the database using hardcoded database credentials stored in the firmware.

1/20/2026
CVE-2025-69426

The Ruckus vRIoT IoT Controller firmware versions prior to 3.0.0.0 (GA) contain hardcoded credentials for an operating system user account within an initialization script. The SSH service is network-accessible without IP-based restrictions. Although the configuration disables SCP and pseudo-TTY allocation, an attacker can authenticate using the hardcoded credentials and establish SSH local port forwarding to access the Docker socket. By mounting the host filesystem via Docker, an attacker can escape the container and execute arbitrary OS commands as root on the underlying vRIoT controller, resulting in complete system compromise.

1/9/2026
CVE-2025-69425

The Ruckus vRIoT IoT Controller firmware versions prior to 3.0.0.0 (GA) expose a command execution service on TCP port 2004 running with root privileges. Authentication to this service relies on a hardcoded Time-based One-Time Password (TOTP) secret and an embedded static token. An attacker who extracts these credentials from the appliance or a compromised device can generate valid authentication tokens and execute arbitrary OS commands with root privileges, resulting in complete system compromise.

1/9/2026
CVE-2023-53983CRITICAL 9.8

Anevia Flamingo XL/XS 3.6.20 contains a critical vulnerability with weak default administrative credentials that can be easily guessed. Attackers can leverage these hard-coded credentials to gain full remote system control without complex authentication mechanisms.

12/30/2025

Similar SeverityHIGH